A12/00045/19Safety recallInjuriesno date · EU Safety Gate
The vehicles might have been fitted with an inappropriate replacement airbag inflator.
Consequently, in the event of an accident the airbag might not properly deploy, increasing the risk of injuries.
Remedy: Type of economic operator taking notified measure(s): Importer
Category of measure(s): Recall of the product from end users
Date of entry into force: Unknown
The authority's notice
A12/00160/20Safety recallInjuriesno date · EU Safety Gate
The ammonium nitrate propellant used in the airbag inflator may experience a material alteration over time due to degradation occurring after prolonged exposure to high absolute humidity, high temperatures and high-temperature cycling. In the event of an airbag being deployed, it may deploy too slowly or the excessive internal pressure may cause the inflator body to rupture and metal fragments may pass through the cushion material causing injury to the occupants.
Remedy: Type of economic operator taking notified measure(s): Importer
Category of measure(s): Recall of the product from end users
Date of entry into force: Unknown
The authority's notice
A12/00376/20Safety recallInjuriesno date · EU Safety Gate
The gas generator of the passenger airbag may be defective.
This may result in uncontrolled inflation and release of metal fragments when the airbag is activated, causing injuries to the occupants.
Remedy: Type of economic operator taking notified measure(s): Manufacturer
Category of measure(s): Recall of the product from end users
Date of entry into force: Unknown
The authority's notice
A12/1334/19Safety recallInjuriesno date · EU Safety Gate
The ammonium nitrate propellant used in the airbag inflator may degrade over time due to propellant degradation occurring after prolonged exposure to high absolute humidity, high temperatures and high-temperature cycling. In the event of an airbag being deployed, the excessive internal pressure may cause the inflator body to rupture and metal fragments may pass through the cushion material causing injury to the occupants.
Remedy: Type of economic operator taking notified measure(s): Importer
Category of measure(s): Recall of the product from end users
Date of entry into force: Unknown
The authority's notice
A12/1740/18Safety recallInjuriesno date · EU Safety Gate
The ammonium nitrate propellant used in the air bag inflator may degrade over time due to heat cycles and exposure to moisture. In the event of the airbag being deployed, the excessive internal pressure may cause the inflator body to rupture and metal fragments may pass through the cushion material causing injury to the rider.
Remedy: Type of economic operator taking notified measure(s): Importer
Category of measure(s): Recall of the product from end users
Date of entry into force: Unknown
The authority's notice