SR/02180/26Safety recallFire7 July 2026 · EU Safety Gate
The RSW22 starter with reinforced water tightness (RWT) may experience increased abrasion of the magnetic contact, causing deposits to build up at the lowest point inside the relay. These deposits may increase relay contact resistance, leading to starting failures or short circuits. If a short circuit occurs, either when attempting to start the vehicle or while driving due to vibration-related movement of the deposits, it could cause a thermal event and increase the risk of fire. The product does not comply with the Regulation on the approval and market surveillance of motor vehicles and their trailers, and of systems, components and separate technical units intended for such vehicles.
Remedy: Type of economic operator taking notified measure(s): Manufacturer
Category of measure(s): Recall of the product from end users
Date of entry into force: 07/07/2026
The authority's notice
SR/00551/26Safety recallFire30 January 2026 · EU Safety Gate
The failure concerns the RSW22 starter, type RWT (reinforced for watertightness). Increased abrasion of the magnetic contact can lead to the formation of deposits at the lowest point of the relay interior. This in turn can increase the resistance of the relay contact, causing accidental ignition or even short circuits, possibly leading to a thermal reaction and fire. The product does not comply with the Regulation on the approval and market surveillance of motor vehicles and their trailers, and of systems, components and separate technical units intended for such vehicles.
Remedy: Type of economic operator taking notified measure(s): Manufacturer
Category of measure(s): Recall of the product from end users
Date of entry into force: 30/01/2026
The authority's notice
SR/00568/26Safety recallFire30 January 2026 · EU Safety Gate
The failure concerns the RSW22 starter, type RWT (reinforced for watertightness). Increased abrasion of the magnetic contact can lead to the formation of deposits at the lowest point of the relay interior. This in turn can increase the resistance of the relay contact, causing accidental ignition or even short circuits, possibly leading to a thermal reaction and fire. The product does not comply with the Regulation on the approval and market surveillance of motor vehicles and their trailers, and of systems, components and separate technical units intended for such vehicles.
Remedy: Type of economic operator taking notified measure(s): Manufacturer
Category of measure(s): Recall of the product from end users
Date of entry into force: 30/01/2026
The authority's notice
SR/00569/26Safety recallFire30 January 2026 · EU Safety Gate
The failure concerns the RSW22 starter, type RWT (reinforced for watertightness). Increased abrasion of the magnetic contact can lead to the formation of deposits at the lowest point of the relay interior. This in turn can increase the resistance of the relay contact, causing accidental ignition or even short circuits, possibly leading to a thermal reaction and fire. The product does not comply with the Regulation on the approval and market surveillance of motor vehicles and their trailers, and of systems, components and separate technical units intended for such vehicles.
Remedy: Type of economic operator taking notified measure(s): Manufacturer
Category of measure(s): Recall of the product from end users
Date of entry into force: 30/01/2026
The authority's notice
A12/00976/22Safety recallFire, Injuriesno date · EU Safety Gate
The micro gas generator inside the seat belt retractor may not have been manufactured to specifications. This may lead to an impairment of the restraint function in case of an accident, increasing the risk of injury. Moreover, there may be spark formation in case of a pressure release outside of the inflator damaged tube, increasing the risk of fire. The product does not comply with the Regulation on the approval and market surveillance of motor vehicles and their trailers, and of systems, components and separate technical units intended for such vehicles.
Remedy: Type of economic operator taking notified measure(s): Manufacturer
Category of measure(s): Recall of the product from end users
Date of entry into force: Unknown
The authority's notice
A12/01377/22Safety recallFireno date · EU Safety Gate
Defects in the winding of cell-internal foils in the high-voltage batteries can lead to the occurrence of increased self-discharge. This can cause high voltage cell modules to overheat, increasing the risk of fire.
The product does not comply with the Regulation on the approval and market surveillance of motor vehicles and their trailers, and of systems, components and separate technical units intended for such vehicles.
Remedy: Type of economic operator taking notified measure(s): Manufacturer
Category of measure(s): Recall of the product from end users
Date of entry into force: Unknown
The authority's notice
A12/01718/22Safety recallInjuriesno date · EU Safety Gate
The front safety belt on the left side may be faulty. This can increase the risk of injury in the event of an accident. The product does not comply with the requirements laid down in the Regulation on the approval and market surveillance of motor vehicles and their trailers, and of systems, components and separate technical units intended for such vehicles.
Remedy: Type of economic operator taking notified measure(s): Manufacturer
Category of measure(s): Recall of the product from end users
Date of entry into force: Unknown
The authority's notice